0
$\begingroup$

I learned that the time constant can be computed as $\frac{1}{2 \pi f_0}$, where $f_0$ is the half-power cutoff frequency of a high-pass filter.

However, I was wondering how the time constant and the half-power cutoff frequency can be related. For example, if the half-power cutoff frequency is 2 Hz, why must the time constant be $\frac{1}{2 \pi (2 \text{ Hz})}$ seconds? Why can't it be some arbitrary number, as long as at that time the output reaches $\frac{1}{e}$ of the starting value?

My knowledge of signal processing is limited to a very basic understanding of Fourier analysis and filtering, so a bit more illustration would be appreciated.

$\endgroup$
3
  • 1
    $\begingroup$ You're mixing terms. If you take a simple lowpass RC filter, the (half-power) cutoff, or corner frequency is your $f_0$, and the pulsation, $\omega_0=2\pi f_0$ with $f_0=\frac{1}{2\pi RC}$, where RC is the time constant. This means that the time constant is directly proportional to the frequency (and pulsation), and can only have a fixed value relative to the frequency. That's why it's called time-constant. $\endgroup$ Commented Aug 6, 2018 at 6:22
  • $\begingroup$ @aconcernedcitizen The question is about a high pass filter not a low pass filter. $\endgroup$ Commented Aug 6, 2018 at 9:02
  • $\begingroup$ @DilipSarwate That was for the OP to extrapolate, while also trying to clear out the meaning of the terms OP used. $\endgroup$ Commented Aug 6, 2018 at 16:43

1 Answer 1

1
$\begingroup$

If you have a first order high-pass filter with transfer function

$$H(s)=\frac{s}{s+\omega_0}\tag{1}$$

then the squared magnitude of its frequency response is given by

$$|H(j\omega)|^2=\frac{\omega^2}{\omega^2+\omega_0^2}\tag{2}$$

Consequently, for $\omega=\omega_0$ we have

$$|H(j\omega_0)|^2=\frac12\tag{3}$$

and $\omega_0$ clearly is the $3$-dB (half-power) cut-off frequency.

In the time domain, we could look at the step response of that system. The step response corresponding to the transfer function $(1)$ is

$$s(t)=e^{-t/T}u(t),\quad T=\frac{1}{\omega_0}\tag{4}$$

where $u(t)$ is the unit step function. So the time constant $T$ and the $3$-dB cut-off frequency are inverses of each other. This is what you get from the math (Fourier transform).

I'll try to give you some intuition and insight into this result. In general a high-pass does not pass DC (i.e., a constant value), so after the step has been applied at the input, the output must decay to zero because the value of the step function is constant after the step has occurred. The higher the cut-off frequency $\omega_0$, the faster the output must decay to zero, because the filter suppresses low frequencies better than a filter with a lower cut-off frequency. So a high value for $\omega_0$ implies a smaller time constant $T$. You can also look at it from the other side. Assume an extremely low cut-off frequency $\omega_0\approx 0$. This means that the filter hardly suppresses anything, i.e., it leaves the input almost unchanged. So at the output you will observe almost the same as at the input, i.e., a step. Only after a very long time will the output decay to zero (because DC is suppressed, after all). So a small value for $\omega_0$ corresponds to a large value of $T$.

$\endgroup$

Your Answer

By clicking “Post Your Answer”, you agree to our terms of service and acknowledge you have read our privacy policy.

Not the answer you're looking for? Browse other questions tagged or ask your own question.